Escalator entrance Induction

The Detector at the entrance of escalator

Escalator entrance detector
THE ENTRANCE DETECTOR OF ESCALATORS

The Detector at the entrance of escalator

The Detector at the entrance of escalator

○ from outside light, the object color, material interference
○ intelligent self-learning, adapt to environmental changes, to avoid malfunction
○ cost structure is simple and easy to install high
Product Overview SYSTEM OVERVIEW

PE100 escalator inlet probe (hereinafter referred to as the detector) is based on an analog signal, digital signal processing is based on the principle of the imaging object through the design of a high-performance intelligent detection means. This product is designed for supporting the use of energy-efficient escalator designed detectors installed at the entrance to the escalator, when the passenger enters the predetermined range, the detector automatically send a signal to start the escalator, escalators, elevators started based on this signal, when the passengers to leave the escalator after a stop signal detector, stop elevators and escalators based on this signal, so as to achieve energy saving.
This product meets the “GB16899-1997 escalators and moving walkways manufacture and installation of safety norms,the relevant requirements.

THE ENTRANCE DETECTOR OF ESCALATORS

THE ENTRANCE DETECTOR OF ESCALATORS

Product Features PRODUCT FEATURES

○ non-contact detection
○ detection area of 110 ± 15 ° horizontal and vertical 60 ± 10 ° conical
○ sensors are waterproof and dustproof treatment, can effectively prevent dew, rain and dust intrusion
○ detector with intelligent self-learning function, for a variety of complex environments
○ sensor is not affected by sunlight, temperature, humidity, fog and other weather environment. Is not affected by the color object detection
○ only a single entrance sensor
○ detection range can be adjusted according to need as 1.3 meters to 2 meters, the output of the delay may be between 3 seconds and 100 seconds

Escalator entrance detector

Escalator entrance detector

Technical indicators TECHNICAL INDEX

Operating voltage; AC220V (allowable range AC176V ~ AC264V)
Working Current: ≤20mA
Minimum detectable distance: 100mm
Detection of the most remote setting range: 1.3 meters to 2 meters
Sensor detection angle: horizontal 110 ± 15 (degrees), the vertical 60 ± 10 (degrees)
Output: relay contact output, normally closed normally open output
Output capacity: DC30V / 1A, AC125V / 0.5A
Environment: Temperature -10 ℃ ~ + 50 ℃
Relative humidity: ≤95%, non-condensing
Host Dimension: 136mm × 70mm × 45mm
Sensor Dimensions: 41.66mm × 35.93mm
Host shell materials and colors: aluminum, silver and white
Sensor sheath material and color: engineering rubber, black
Weight: about 500g
Life: not less than 3 years
Sensor Configuration: 1 to 2 sensor (only a single entrance)

Otis 506 inlet GAB438BNX5/6

Otis 506 elevator inlet GAB438BNX5 GAB438BNX6

nx5 nx6 gab438bnx6 gab438bnx5

otis 506 elevator inlet GAB438BNX5 GAB438BNX6
otis access inlet panel GAB438BNX5 GAB438BNX6
otis escalator bracket GAB438BNX5 GAB438BNX6

We also offer basic models of inlet GAB438BNX1 GAB438BNX2 GAB438BNX3 GAB438BNX4
OTIS 506 escalator parts GAB438BNX5 GAB438BNX6